Ultraviolet light is the main cause of degradation of almost all materials exposed to the outdoors.It is mainly used to simulate the damage effect of sunlight, humidity and temperature on materials.Material aging includes fading, light loss, strength ...

Order hotline:076985050140
I. product parameters
Studio size: 1140mm x 400mm x 380 mm
External dimension: 1300mm x 500mm x 1460mm
Center distance of light: 70mm
Distance of the specimen from the nearest parallel surface of the lamp surface: about 50mm
Wavelength range: UV-A wavelength range is 315~400nm
Radiation intensity: 1.5w/m2/340nm
The temperature resolution: 0.1 ℃
Light temperature range: 50 ℃ ~ 70 ℃ / temperature tolerance of + / - 3 ℃
Condensation temperature range: 40 ℃ ~ 60 ℃ / temperature tolerance of + / - 3 ℃
The blackboard thermometer range: 30 ~ 80 ℃ / tolerance of + / - 1 ℃
Temperature control mode: PID self-tuning temperature control mode
Humidity range: about 45%~70%R.H(light condition)/over 98% (condensation condition)
Flume requirement: water depth is no more than 25mm and there is automatic water supply controller
Standard specimen size: 75 x 150mm 48pcs
Suggested that the instrument use environment: 5 ~ 35 ℃, 40% ~ 85% r. H, 300 mm from the wall
2.The main function
The uva-340 fluorescent uv lamp is adopted as the light source in the uva-340 uv accelerated aging test box, which can simulate the damage caused by sunshine, rain and dew.UV weather box USES fluorescent UV lamp to simulate the effect of sunlight, and condenses moisture to simulate dew.In order to obtain the result of weather resistance, the tested material was placed in the loop program of light and moisture alternating under a certain temperature.UV cases can reproduce the damage that occurs outdoors over months or years in a matter of days or weeks.Hazard types include: discoloration, discoloration, loss of light, powder light, cracking, turbidity, bubble, brittle, strength, decay and oxidation.The machine contains sprinkling device.
This uv-accelerated aging test chamber can simulate the environmental conditions such as ultraviolet, rain, high temperature, high humidity, condensation and darkness in natural climate. By reproducing these conditions, it can be combined into a loop and let it automatically execute the loop number.This is how the uv aging test chamber works.In this process, the equipment can monitor the blackboard temperature and the water tank temperature automatically.Through the configuration of the radiation measurement and control device (optional), the light irradiance can be measured and controlled, so that the irradiance can be stabilized at 0.76W/m2/340nm or designated setting value, and the service life of the lamp can be greatly extended.
International testing standards:
ASTM G 153, ASTM G 154, ASTM D 4329, ASTM D 4799,ASTM D 4587, SAE
J2020, ISO 4892 all current uv aging test standards.
3.Component is introduced
A.Light source:
The light source is made of 8 imported uv fluorescent lamps with rated power of 40W.Uv fluorescent tubes, distributed in the machine
4 on each side.There are uva-340 and uvb-313 light sources for users to choose the configuration.
The luminous spectral energy of uva-340 lamp is mainly concentrated at the wavelength of 340nm.
The luminescence spectrum of uvb-313 lamp is mainly around the wavelength of 313nm.
We use the uva-340 lamp tube
Since the energy output of fluorescent lights will gradually decline with time, in order to reduce the impact of the experiment caused by the optical energy attenuation,
Therefore, the test box is replaced by a new lamp for every 1/4 of the fluorescent lamp life of all 8 lamps
The lamp tube, thus, the uv light source is always composed of the new lamp and the old lamp, thus obtaining a constant output of light energy.
The effective service life of lamp tube is about 1600 hours.
B.Electrical and gas control system:
A. the temperature of the blackboard and the condensation temperature are controlled by the controller.
B. the rest are basically imported electronic components.
Irradiation uniformity: no more than 4% (on the surface of the sample)
Blackboard temperature monitoring: use standard Pt-100 blackboard temperature
Sensor,
Accurately control the surface temperature of the sample during the test.
The board temperature setting range: BPT 40-75 ℃;
But the temperature protection inside the machine
Place the actual maximum limit temperature of 93 ℃ + / - 10%.
The board temperature control precision: plus or minus 0.5 ℃,
C. Water tank temperature monitoring: during the loop test, one test section is the dark condensation process, which requires the internal energy of the box
The higher temperature of saturated water vapor, when the water vapor meets relatively cold surface, will condense on the surface of the sample
Water.
The water tank is located in the lower part of the box with a built-in electric heater.
Tank temperature control range: 40 ~ 60 ℃
D. The test box is equipped with a time controller with a range of 0~530H and power failure memory function.
E. safety protection device:
The temperature in the cabinet overtemperature protection: when the temperature over 93 ℃ plus or minus 10%, the machine will automatically cut off the electricity and heater tubes
The source is supplied and cooled into an equilibrium state.
Low water level alarm to prevent the heater from burning.
C.Standard sample holder:
A number of 75-by-150mm is randomly equipped with ieds
Or 75 x 290 mm standard sample holder,
The maximum thickness of the sample can be up to 20mm.
Non-standard size users need to specify when ordering.
The sample holder can be loaded directly without the need of sample holder.
Hold 14 rows/sides of the standard sample, one of them on the back with a chalkboard thermometer.
The machine opens easily.
D.Box material:
Stainless steel SUS304 stainless steel plate is used for both sides
The enclosure adopts SUS304 stainless steel plate
The samplesholder is made of stainless steel and aluminum alloy into a mesh frame for easy access to samples
E.Overall situation:
Upper size: about H1370mm x W1350mm x D 530 mm
Weight: about 150 kg
F.The main machine of KUV3 requires working environment:
Power supply: 220V + / -5%, single-phase three-wire, 50Hz, 8A, 10A slow fuse required.
Environment: 5 ~ 35 ℃, 0 ~ 80% RH, well ventilated, clean indoor environment.
The floor area of this office is about 234 by 353cm
Drain: drains are required on the floor near the main engine.
For ease of movement, the bottom of the instrument installed casters, fixed position
The position of the testing machine is fixed with a u-shaped ring.
Iv. Control instruments
The real color touch screen PID temperature intelligent control instrument is used to control temperature with high accuracy and good stability.
Meet the standards
GB/t14522-93 GB/T16422.3-1997 GB/t16585-96, etc
* NOT NULLProcurement:Uv aging test chamber
* Contact: Please enter your name
* phone: Please input the telephone
E-Mail:
* Blanket PO:
For Senior Visiting StudentprocurementThe quantity and description of the products make it convenient for us to prepare uniformly。
* CAPTCHA: Can't see? Click on the change

Contact Us


Dongguan Hongjin test instrument co,.ltd
HOTLINE:076985050140

consultation:0769-85050140

Fax:0769-85050141

E-mail:[email protected]

WEB:www.hongyu17-group.com

ADD:Building D, No. 68, Xixing 3rd Street, Changping Town, Dongguan, Guangdong, China (Mainland)



  • 官方微信